当前位置: 首页 > 期刊 > 《中华心血管病杂志》 > 1998年第4期
编号:10668554
QT离散度的方法学及其正常参考值研究
http://www.100md.com 《中华心血管病杂志》 1998年第4期
QT离散度|心电描记术|参考值,关键词:
     刘艳 郭映春 马奕 崔长琮 张莉 G.Michael Vincent 710061西安医科大学第一附属医院心内科[刘艳(博士研究生)、郭映春、马奕、崔长琮(导师)];美国UTAH大学LDS医院(张莉、G.Michael Vincent) 中华心血管病杂志 1998 0 26 4


    关键词:QT离散度;心电描记术;参考值 期刊 zhxxgbzz 0 *临床研究* fur -->


    

【摘要】 目的 探讨QT离散度(QTd)的正常参考值及在不同心电图记录纸速、不同时间重复测量、不同测量方法之间的可重复性。方法 分别以纸速25mm/s、50mm/s记录504例健康成人体表12导联同步心电图,用手工分规和电脑半自动测量QTd,比较不同心电图纸速、不同时间重复测量、不同测量方法之间的可重复性。结果 (1)同一或不同测量者不同时间内重复测量的QTd、QTcd、RR间期显著相关,r分别为0.93、0.95、0.99,P均小于0.01。(2)计算机半自动测量与手工分规测量的QT、QTd显著相关,r分别为0.84、0.88,P均小于0.01。(3)在25mm/s纸速与50mm/s纸速的心电图分别测量QTd、QTcd、RR间期,两次结果相关性好,r分别为0.86、0.84、0.96,P均<0.05。(4)用不同方法测量QTd、QTcd的结果差异无显著性,其平均误差小于7ms。(5)QTd、QTcd的正常参考值为45±13ms、49±14ms。结论 ①QTd在不同心电图记录纸速、不同时间重复测量、不同测量方法之间显著相关,可重复性好。②QTd的正常参考值为45±13ms,范围为20~70ms。

    The study of methodology and normal value of QT dispersion(QTd) Liu Yan, Guo Yingchun, Ma Yi, et al.Department of Cardiology, First Affiliated Hospital, Xi an Medical University,Xi an710061

    
Abstract Objective This study wasaimed to investigate the normal value and reproducibility of QTd in different paperspeeds, different times of measurements repeated by same or different observers, and tocompare user-interactive computer (mouse and computer screen) with manual dividersmeasurements.Methods The 12-lead synchronyelectrocardiograms (ECGs) in 504 healthy people (age:18-60 years) were recorded at 25mm*s-1 and 50mm*s-1 paper speeds. All ECGs at 50mm*s-1 were analysed fornormal value of QTd by manual dividers. 60 of 504 ECGs chosen randomly were re-analysed atleast 1 month after the first measurment by both manual and computer methods. The ECGs at25mm*s-1 of these 60 people were measured by manual dividers only.Results (1) The QTd, QTcd showed a significant correlation between thedifferent paper speeds (25mm*s-1 and 50mm*s-1 ), differentmeasurements repeated by same or different observers, and different methods, the r valueswere from 0.84 to 0.99, P<0.05. The repeat measurement errors of QTd was 6ms,user-interactive computer and manual dividers measurement errors were 6ms, 25mm*s-1 and 50mm*s-1 ECGs errors of QTd was 7ms. (2)The QTd QTcd QRSd of these healthyadults were 45±13 (20-70),49±14 (25-75), 29±11 (10-65)ms respectively.Conclusion There are good correlations and reproducibility of QTd in differentpaper speeds, repea-ting measurements by same or different observers, and the differentways in measurement.

    
Key words QT dispersion electrocardiography reference values

     ......


您现在查看是摘要页,全文长 13143 字符