HPLC法测定人唾液中卡马西平浓度及其药代动力学
卡马西平,,色谱法,高压液相;卡马西平;唾液;药代动力学,1材料和方法,2结果,3讨论,【参考文献】
Determination of carbamazepine concentration in human saliva by HPLC and its pharmacokinetic studyTANG Zhe,WEN AiDong,WU Yin, ZHAO Lei, LI HongLi, SHI Ru
Department of Pharmacy,Xijing Hospital,Fourth Military Medical University, Xian 710033, China
【Abstract】 AIM: To determine carbamazepine(CBZ) concentration in human saliva by HPLC and study its pharmacokinetics. METHODS: Shimpack CLCODS C18 (150 mm×6 mm, 5 μm) spectrum analytical column was used and methanolwater(53∶47)was adopted as the mobile phase. Flow rate was 1.0 mL·min-1, detection wavelength was 212 nm, column temperature was 23℃ and the dosage of CBZ was 50 μL. The pharmacokinetic parameters of CBZ tablets taken by 6 healthy volunteers at a single oral dose of 200 mg were calculated according to CBZ concentration in saliva. RESULTS: The standard curve was linear (r=0.999) within the range of 0.40~4.32 mg·L-1 for CBZ. The limit of detection in saliva was 30 μg·L-1 (S/N≥3). The average recovery was 99.17%-104.80%;the interday RSD and intraday RSD was 2.6%-4.9% and 3.0%-8.6% respectively.The results showed that the pharmacokinetics of CBZ was in accordance with the onecompartment open model. Tmax, Cmax, ke, T1/2 and AUC(0~inf) was (4.50±3.15) h, (1.52±0.22) mg·L-1, (0.0090±0.0006) h-1, (77.16±5.26) h and (132.18±8.82) mg ·h·L-1 respectively. After single dosing, the concentrationtime curve of CBZ in saliva presented multiple peaks. CONCLUSION: This method is simple, quick and specific, and can be used to determine CBZ concentration in human saliva and to study its pharmacokinetics. ......