颈椎椎体次全切钛网钉板系统的临床应用
颈椎;前路减压;钛网钉板植入融合,,]颈椎;前路减压;钛网钉板植入融合,1对象与方法,2结果,3讨论,参考文献
[摘要]目的探讨颈椎前路椎体次全切钛网钉板做植骨融合的临床效果。方法自2002年3月至2003年3月间应用颈前路椎体次全切钛网钉板植入融合治疗颈椎管狭窄疾病18例,其中2例患者作了2节椎体次全切,3节椎间隙减压。术后观察减压、固定、融合及神经功能恢复情况,并行X线或CT检查。结果患者获6~12个月随访,神经功能得到不同程度改善,无加重情况。椎间隙无高度丢失、无成角,均获得骨性融合。3天后在颈围领固定下下床活动,4周后可恢复较轻工作。结论此术式可避免传统手术方法的缺点,不取髂骨,融合率高,稳定性好,并减压彻底,疗效好,是一种值得推广的新技术。[关键词]颈椎;前路减压;钛网钉板植入融合
Study on clinical application of titanium mesh cage combined with screwplate system for cervical spine subtotal corpectomy
GU Zenghui,HUANG Hongqian,ZHENG Longbao,et al.
Department of Orthopedics,the 117th Hospital of PLA,Hangzhou 310004
[Abstract]ObjectiveTo explore the clinical efficacy of anterior cervical spine subtotal corpectomy with titanium mesh cage combined with screwplate system. Methods18 patients with cervical spinal stenosis were treated by iliac crest autograft with titanium mesh cage and screwplate for anterior cervical spine subtotal corpectomy from March 2002 to March 2003, including 2 cases undergone 2 vertebra subtotal corpectomy and 3 intervertebral height decompression through the disc space. Physical examination, Xray and CT were taken at regular interval postoperatively to assess the recovery of nervous function, anterior decompression, cervical stability and bony fusion. ResultsThe patients were followed up for 6~12 months. The nervous functions were recovered in different levels without deterioration; intervertebral height was not decreased and had no angulations. The patients fixed with collar after operations could get out of bed after 3 days and recover work lightly after 4 weeks. All cases acquired bony fusion. ConclusionsTitanium mesh cage combined with screwplate system for cervical spine subtotal corpectomy has advantages of less trauma for graft, good stability, higher fusion rate, full decompression, satisfactory clinical efficacy over the traditional ways. Therefore, this operative method is a new method and deserves further application in clinic. ......
您现在查看是摘要页,全文长 7824 字符。