新型髓内钉治疗股骨不稳定骨折的生物力学研究
http://www.100md.com 《第四军医大学学报》 2006年第19期
骨钉;骨折固定术,髓内;股骨;骨折;生物力学,,骨钉;骨折固定术,髓内;股骨;骨折;生物力学,0引言,1材料和方法,2结果,3讨论,【参考文献】
     YAN HongWei1, LONG Yong2, WANG KunZheng1, LIU Kai1, HUANG XiangHui1, LIU Jun1, ZHANG KaiFang1, SONG JinHui1

    1Department of Orthopaedics,Second Affiliated Hospital, Medical College, Xian Jiaotong University, Xian 710004, China, 2Department of Epidemiology, School of Preventive Medicine, Fourth Military Medical University, Xian 710033, China

    【Abstract】 AIM: To discuss the possibility and virtues of a new intramedullary nail for treating unsteady femoral fractures. METHODS: The properties of antiaxial compression, antilateral bending and antitorsion of the new interlocking intramedullary nail were tested and compared with those of imported Orthofix interlocking intramedullary nail and AO dynamic compression plate in treating unsteady femoral fracture. RESULTS: In the cases of unsteady fractures, the imported Orthofix nail presented the best antiaxial compression performance and the new nail the second, and the AO compression plate was the worst; the difference was very significant (P<0.01). The AO compression plate showed the best in both antilateral bending and antitorsion, and the new nail performed the second; the differences were also obvious (P<0.01). CONCLUSION: In unsteady fracture, the new developed nails have superior biomechanical characters with a reliable fixation; dynamic compression plate is not the best choice for internal fixation, especially in unsteady fracture; the shape of the narrow part of medullary cavity has a great influence on antilateral bending steady. ......