人工腰椎间盘置换后椎间隙高度变化
假体和植入物;,椎间盘,腰椎;,椎间盘移位;,外科手术;,治疗结果,,假体和植入物;,椎间盘,腰椎;,椎间盘移位;,外科手术;,治疗结果,1对象与方法,2结果
摘要: 目的 观察人工椎间盘置换对维持腰椎间隙高度的作用,探讨人工椎间盘置换术减缓腰腿痛的作用机制。 方法 对20例患者29个节段进行SB Charite Ⅲ型人工椎间盘置换术,于手术前后及随访期间按Mochida’s法测量手术节段及手术相邻节段椎间隙高度,计算椎间隙高度(a)与上位椎体高度(A)的比值(R=a/A);并对患者临床临床表现进行JOA评分。 结果平均JOA评分从术前的(10.80±3.81)分提高到术后的(20.90±2.45)分,经(14.0±6.1)月(6~27月)随访,评分为(25.95±2.01)分,各个期间评分比较差别有统计学意义(P<0.001)。置换节段的R值在术前为(0.366±0.053),术后为(0.524±0.048),随访时为(0.527±0.046);与术前比较,术后及随访时的R值均有明显上升(P<0.001),而术后与随访期间的R值比较差别无统计学意义(P>0.05)。相邻节段在术前、术后及随访期间的R值分别为(0.445±0.076)、(0.461±0.068)和(0.450±0.054),三者比较无统计学意义(P>0.05)。 结论SB Charite Ⅲ型人工椎间盘置换术能有效地恢复置换节段椎间隙高度,对相邻节段椎间隙高度无明显影响;经过随访,椎间隙高度的恢复无明显丢失。关键词: 假体和植入物; 椎间盘,腰椎; 椎间盘移位; 外科手术; 治疗结果
Effects of SB Charite Ⅲ Prosthesis Replacement
on Height of Intervertebral Disc Space
Lin Feiyue, Li Kanghua, Lei Guanghua, Lin Zhangyuan, Yin Xiaoming
1.Department of Orthopedic, Xiangya Hospital, Central South University, Changsha 410008, China
2.Department of Orthopedic, Fujian Provincial Hospital, Fuzhou 350001, China
ABSTRACT: Objective To determine the effects of SB Charite Ⅲ prosthesis replacement on the height of intervertebral disc space. Methods Twentynine protruded lumbar intertebral discs from twenty patients were replaced with SB Charite Ⅲ prosthesis. The lumbar spine Xray images of these patients were studied; the heights of operated and adjacent disc spaces were measured with Mochida’s method at preoperation, postoperation and during followup. The clinical results were evaluated with scoring system of the Japanese Orthopedic Association for low back pain(JOA Score) preand postoperation and during followup. The average followup time was (14.0±6.1) months (6~27 months). ResultsThe average JOA scores at preoperation, postoperation and followup were (10.80±3.81), (20.90±2.45) and (25.95±2.01), respectively(P<0.001). The Mochida'method R values of operated segments at preoperation, postoperation and during followup were (0.366±0.053), (0.524±0.048) and (0.527±0.046), respectively. The R value increased significantly at postoperation and followingup(P<0.001), comparing with which at preoperation. However, the R values between which at postoperation and followup had no significant different(P=0.902). The R values of adjacent segments at preoperation, postoperation and followingup were(0.445±0.076), (0.461±0.068) and (0.450±0.054), respectively, and there had no significant different among these R values (P>0.05). Conclusion SB Charite Ⅲ prosthesis replacement in patients suffering from LDH can relax the sciatica and restore the disc space height. ......
您现在查看是摘要页,全文长 10800 字符。