当前位置: 首页 > 医学版 > 期刊论文 > 大学学报(医药卫生) > 第四军医大学学报 > 2006年 > 第23期
编号:11372687
用于脑部电阻抗断层成像的高稳定性恒流源的设计
http://www.100md.com 《第四军医大学学报》
电阻抗断层成像;恒流源;分布电容;屏蔽驱动,,电阻抗断层成像;恒流源;分布电容;屏蔽驱动,1原理,2方法和结果,3讨论
     Design of a current source with high stability for brain electrical impedance tomography system

    SHI XueTao, YOU FuSheng, HUO XuYang, FU Feng, LIU RuiGang, DONG XiuZhen

    Department of Medical Electronic Engineering, School of Biomedical Engineering, Fourth Military Medical University, Xian 710033, China

    【Abstract】 AIM: To improve the stability of the current source for brain electrical impedance tomography (EIT) data acquisition system. METHODS: A shield guard technique was employed to minimize the shunting effect of the stray capacitance of wires between electrodes and current source. At the same time, an output current compensating method was adopted to compensate the current loss caused by the multiplexers stray capacitance. RESULTS: The simulation results showed that after those methods were used, the maximum relative current error on a 1.5 kΩ load dropped from 7% to 0.4% in working frequency range, and the practical results also showed that the final maximum relative current error on this load was less than 1%. CONCLUSION: The shield guard method for wires and the output current compensating method for current source can effectively improve the stability of current sources output current. ......