HPLC法测定注射用肌苷的含量
【摘要】目的:用高效液相色谱法测定注射用肌苷的含量。方法:采用Kromasil C18柱(5μm 4.6mm×250mm),以甲醇-水(10∶90)作流动相,在248nm紫外波长检测。结果:肌苷在4.23~63.48μg/ml范围内有良好的线性关系(r=0.9999)。低、中、高3个浓度的平均回收率(n=2)分别为101.4%、101.8%、101.1%,RSD为0.46%。结论:该法简便、快速、准确,可作为测定注射用肌苷中肌苷的含量。
【关键词】注射用肌苷;高效液相色谱法;含量测定
【Abstract】ObjectiveA high-performance liquid chromatography (HPLC) was established for the determination of inosine contents in injection.MethodsImpurity in the inosine injection could be separated on Kromasil C18 colnmn (5μm 4.6mm×250mm) using methanol-water (10:90) as mobile phase and UV detector at 248nm.ResultsThe linear range was 4.23~63.48μg/ml(r=0.9999).Average recovery in the lower,moderate and higher inosine concentration groups was respectively 101.4%,101.8% and 101.1%(n=2) with RSD of 0.46%.ConclusionThe method is simple,rapid and accurate.
, http://www.100md.com
【Key words】Inosine injection;HPLC;Concentration determination
【中图分类号】R927.2 【文献标识码】B 【文章编号】1006-1959(2009)06-0244-01
肌苷为微生物发酵制得的辅酶类药物,有改善机体代谢作用,临床用于各种类型的肝脏疾患、心脏疾患、白细胞和血小板减少症、中心视网膜炎及视神经萎缩等。有关标准规定[1],注射用肌苷含量测定采用紫外分光光度法,该方法操作复杂、费时且专属性差。为了有效地分离降解产物,准确测定注射用肌苷含量,本文采用高效液相色谱法(HPLC)测定注射用肌苷中肌苷含量,获得满意结果。
1 仪器与试药
高效液相色谱仪:DIONEX P680 HPLC PUMP泵;DIONEX UVD170U紫外检测仪;Chromeleon Server Monitor工作站。肌苷对照品(含量99.2%,中国药品生物制品检定所),注射用肌苷分别为山西(规格:0.3g批号20060101;2006126);海南(规格:0.2g批号20051201)。甲醇为色谱纯,试验用水为重蒸馏水。
, 百拇医药
2 色谱条件
色谱柱:Kromasil C18(5μm 4.6mm×250mm);流动相:甲醇-水(10:90);检测波长为248nm;流速1.0ml/min;柱温为25℃;进样量20μl。
3 线性关系的考察
3.1 对照品储备液的制备:精密称取对照品10.58mg,置100ml量瓶中,加水溶解并稀释至刻度,摇匀。
3.2 标准曲线的绘制:精密吸取对照品储备液1.0、2.0、3.0、5.0、10.0、15.0ml,分别置25ml量瓶中,加水稀释至刻度,摇匀,分别进样20μl,依法测定。以各溶液的浓度为横坐标,以峰面积为纵坐标,绘制工作标准曲线,肌苷的线性回归方程为Y=0.726X+0.068(r=0.9999,n=6),在4.23~63.48μg/ml浓度范围内呈现良好的线性关系。
, http://www.100md.com
4 精密度试验
取含量测定项下肌苷对照品溶液20μl注入液相色谱仪,重复进样5次,测定峰面积,结果肌苷峰面积的RSD为0.14%(n=5),表明本法精密度良好。
5 重复性试验
按供试品溶液制备方法处理同一批号样品5份,测得肌苷的平均含量为105.5%,RSD为1.3%(n=5),表明本法重复性良好。
6 回收率试验
精密称取已知含量的样品适量(约相当于肌苷50mg),分别精密加入肌苷对照品约40mg、50mg、60mg,置100ml量瓶中,加水溶解并稀释至刻度,摇匀。精密量取2ml,置100ml量瓶中,加水稀释至刻度,摇匀。按样品含量测定相下方法测定并计算回收率。低、中、高3个浓度的平均回收率(n=2)分别为101.4%、101.8%、101.1%,RSD为0.46%。
, 百拇医药
7 稳定性试验
取含量测定项下肌苷对照品溶液20μl分别于0、2、4、6、8、12、24h测定,测得肌苷HPLC峰面积为0.9%,表明溶液在24h内稳定。
8 样品测定
8.1 对照品的制备:取“3.1”项下对照品储备液5ml置25ml量瓶中,加水稀释至刻度,摇匀,即得对照品溶液。
8.2 供试品的制备:取装量差异项下的内容物,混合均匀,精密称取适量(约相当于肌苷0.1g),置100ml量瓶中,加水约70ml,充分振摇使肌苷溶解,用水稀释至刻度,摇匀,滤过,精密量取2ml,置100ml量瓶中,加水稀释至刻度,摇匀。
8.3 含量测定:精密量取“8.2”项下供试品溶液20μl注入液相色谱仪,记录色谱图,同法测定对照品溶液,按外标法以峰面积计算其含量。
, http://www.100md.com
9 讨论
9.1 检测波长的选择:由于肌苷在酸性和高温条件下易分解为次黄嘌呤,且次黄嘌呤在249nm的波长处有最大吸收,肌苷的最大吸收波长为248nm[2],故选择248nm作为检测波长。
9.2 流动相的选择:经过实验,选择了甲醇-水(10∶90)为流动相,能将杂质(降解产物)与肌苷分离,且分离效果较好,保留时间合适[3]。
参考文献
[1]国家食品药品监督管理局.标准(试行)YBH12992004
[2] 李金屏.肌苷及制剂质量标准修订起草说明.2005年版药典增修订情况介绍
[3] 国家药典委员会.中华人民共和国药典二部[M].北京:化学工业出版社,2005:205
作者单位:455000 河南省安阳市药品检验所, http://www.100md.com(石保龙)
【关键词】注射用肌苷;高效液相色谱法;含量测定
【Abstract】ObjectiveA high-performance liquid chromatography (HPLC) was established for the determination of inosine contents in injection.MethodsImpurity in the inosine injection could be separated on Kromasil C18 colnmn (5μm 4.6mm×250mm) using methanol-water (10:90) as mobile phase and UV detector at 248nm.ResultsThe linear range was 4.23~63.48μg/ml(r=0.9999).Average recovery in the lower,moderate and higher inosine concentration groups was respectively 101.4%,101.8% and 101.1%(n=2) with RSD of 0.46%.ConclusionThe method is simple,rapid and accurate.
, http://www.100md.com
【Key words】Inosine injection;HPLC;Concentration determination
【中图分类号】R927.2 【文献标识码】B 【文章编号】1006-1959(2009)06-0244-01
肌苷为微生物发酵制得的辅酶类药物,有改善机体代谢作用,临床用于各种类型的肝脏疾患、心脏疾患、白细胞和血小板减少症、中心视网膜炎及视神经萎缩等。有关标准规定[1],注射用肌苷含量测定采用紫外分光光度法,该方法操作复杂、费时且专属性差。为了有效地分离降解产物,准确测定注射用肌苷含量,本文采用高效液相色谱法(HPLC)测定注射用肌苷中肌苷含量,获得满意结果。
1 仪器与试药
高效液相色谱仪:DIONEX P680 HPLC PUMP泵;DIONEX UVD170U紫外检测仪;Chromeleon Server Monitor工作站。肌苷对照品(含量99.2%,中国药品生物制品检定所),注射用肌苷分别为山西(规格:0.3g批号20060101;2006126);海南(规格:0.2g批号20051201)。甲醇为色谱纯,试验用水为重蒸馏水。
, 百拇医药
2 色谱条件
色谱柱:Kromasil C18(5μm 4.6mm×250mm);流动相:甲醇-水(10:90);检测波长为248nm;流速1.0ml/min;柱温为25℃;进样量20μl。
3 线性关系的考察
3.1 对照品储备液的制备:精密称取对照品10.58mg,置100ml量瓶中,加水溶解并稀释至刻度,摇匀。
3.2 标准曲线的绘制:精密吸取对照品储备液1.0、2.0、3.0、5.0、10.0、15.0ml,分别置25ml量瓶中,加水稀释至刻度,摇匀,分别进样20μl,依法测定。以各溶液的浓度为横坐标,以峰面积为纵坐标,绘制工作标准曲线,肌苷的线性回归方程为Y=0.726X+0.068(r=0.9999,n=6),在4.23~63.48μg/ml浓度范围内呈现良好的线性关系。
, http://www.100md.com
4 精密度试验
取含量测定项下肌苷对照品溶液20μl注入液相色谱仪,重复进样5次,测定峰面积,结果肌苷峰面积的RSD为0.14%(n=5),表明本法精密度良好。
5 重复性试验
按供试品溶液制备方法处理同一批号样品5份,测得肌苷的平均含量为105.5%,RSD为1.3%(n=5),表明本法重复性良好。
6 回收率试验
精密称取已知含量的样品适量(约相当于肌苷50mg),分别精密加入肌苷对照品约40mg、50mg、60mg,置100ml量瓶中,加水溶解并稀释至刻度,摇匀。精密量取2ml,置100ml量瓶中,加水稀释至刻度,摇匀。按样品含量测定相下方法测定并计算回收率。低、中、高3个浓度的平均回收率(n=2)分别为101.4%、101.8%、101.1%,RSD为0.46%。
, 百拇医药
7 稳定性试验
取含量测定项下肌苷对照品溶液20μl分别于0、2、4、6、8、12、24h测定,测得肌苷HPLC峰面积为0.9%,表明溶液在24h内稳定。
8 样品测定
8.1 对照品的制备:取“3.1”项下对照品储备液5ml置25ml量瓶中,加水稀释至刻度,摇匀,即得对照品溶液。
8.2 供试品的制备:取装量差异项下的内容物,混合均匀,精密称取适量(约相当于肌苷0.1g),置100ml量瓶中,加水约70ml,充分振摇使肌苷溶解,用水稀释至刻度,摇匀,滤过,精密量取2ml,置100ml量瓶中,加水稀释至刻度,摇匀。
8.3 含量测定:精密量取“8.2”项下供试品溶液20μl注入液相色谱仪,记录色谱图,同法测定对照品溶液,按外标法以峰面积计算其含量。
, http://www.100md.com
9 讨论
9.1 检测波长的选择:由于肌苷在酸性和高温条件下易分解为次黄嘌呤,且次黄嘌呤在249nm的波长处有最大吸收,肌苷的最大吸收波长为248nm[2],故选择248nm作为检测波长。
9.2 流动相的选择:经过实验,选择了甲醇-水(10∶90)为流动相,能将杂质(降解产物)与肌苷分离,且分离效果较好,保留时间合适[3]。
参考文献
[1]国家食品药品监督管理局.标准(试行)YBH12992004
[2] 李金屏.肌苷及制剂质量标准修订起草说明.2005年版药典增修订情况介绍
[3] 国家药典委员会.中华人民共和国药典二部[M].北京:化学工业出版社,2005:205
作者单位:455000 河南省安阳市药品检验所, http://www.100md.com(石保龙)