多叶准直器在调强放射治疗中的进展和临床应用(2)
[8]Su S,Han F,Zhao C, et al. Long-term outcomes of earlystage nasopharyngeal carcinoma patients treated with intensity-modulated radiotherapy alone [J].Int J Radiat Oncol Biol Phys,2012,82(1):327-333.
[9]Gong YL, Wang SC, Zhou L, et al. Dosimetric comparison using different multileaf collimators in intensity -modulated radiotherapy for upper thoracic esophageal cancer[J]. Radiat Oncol, 2010,5:65-71.
[10]Wang L, Hoban P, Paskalev K, et al. Dosimetric advantage and clinical implication of a micro-multileaf in the treatment of prostate with intensity-modulated radiotherapy[J]. Med Dosim,2005, 30:97-103.
[11]Abe E, Mizowaki T, Norihisa Y, et al. Impact of multileaf collimator width on intraprostatic dose painting plans for dominant intraprostatic lesion of prostate cancer [J]. J Appl Clin Med Phys, 2010, 11:144-154.
[12]Nill S, Tücking T, Münter MW, et al. Intensity modulated radiation therapy with multileaf collimators of different leaf widths: a comparison of achievable dose distributions [J]. Radiother Oncol,2005,75:106-111.
[13]范廷勇,李建彬.MLC叶片宽度对IMRT计划的影响[J]. 肿瘤防治杂志,2005,12(8):611-612.
[14]张富利,刘清智等.基于配置不同类型MLC 叶片加速器的宫颈癌术后调强放疗计划评估[J].中国医学物理学杂,2013,30(5)4383-4386.
[15]Implications of a high-definition multileaf collimator (HD-MLC) on treatment planning techniques for stereotactic body radiation therapy (SBRT): a planning study., 百拇医药(杨超凤 杨海明 付庆国 邓烨)
[9]Gong YL, Wang SC, Zhou L, et al. Dosimetric comparison using different multileaf collimators in intensity -modulated radiotherapy for upper thoracic esophageal cancer[J]. Radiat Oncol, 2010,5:65-71.
[10]Wang L, Hoban P, Paskalev K, et al. Dosimetric advantage and clinical implication of a micro-multileaf in the treatment of prostate with intensity-modulated radiotherapy[J]. Med Dosim,2005, 30:97-103.
[11]Abe E, Mizowaki T, Norihisa Y, et al. Impact of multileaf collimator width on intraprostatic dose painting plans for dominant intraprostatic lesion of prostate cancer [J]. J Appl Clin Med Phys, 2010, 11:144-154.
[12]Nill S, Tücking T, Münter MW, et al. Intensity modulated radiation therapy with multileaf collimators of different leaf widths: a comparison of achievable dose distributions [J]. Radiother Oncol,2005,75:106-111.
[13]范廷勇,李建彬.MLC叶片宽度对IMRT计划的影响[J]. 肿瘤防治杂志,2005,12(8):611-612.
[14]张富利,刘清智等.基于配置不同类型MLC 叶片加速器的宫颈癌术后调强放疗计划评估[J].中国医学物理学杂,2013,30(5)4383-4386.
[15]Implications of a high-definition multileaf collimator (HD-MLC) on treatment planning techniques for stereotactic body radiation therapy (SBRT): a planning study., 百拇医药(杨超凤 杨海明 付庆国 邓烨)