[摘要] 目的 评价我科Sysmex XE-5000与XS-800i血细胞分析仪对红细胞碎片干扰血小板(PLT)检测结果的性能。方法 分别用XE-5000电阻抗法(PLT-I)、XE-5000荧光法(PLT-O)、XS-800i电阻抗法检测经红细胞碎片干扰后的标本,运用SPSS12.0进行数据回归分析和配对t检验。结果 正常对照组的样本用三种方法检测,结果重复性好,差异不具有统计学意义(P>0.05)。在高浓度组中三种方法的检测结果都与对照组有明显的差异(P<0.01);而在低浓度组PLT-O法显示了其良好的抗红细胞碎片干扰性,即干扰前后结果不具有统计学差异(P>0.05)。结论 对于受红细胞碎片干扰的血小板检测,XS-800i电阻抗法抗干扰能力与XE-5000 PLT-I法一般,但XE-5000开通荧光通道后,其PLT-O检测结果优于前两者。
[关键词] XE-5000;XS-800i;血小板计数;红细胞碎片干扰试验
[中图分类号] R446 [文献标识码] B [文章编号] 1673-9701(2011)32-79-03
Evaluation of Platelet Count in RBC Fragment Interference Experiment on SYSMEX XE-5000 and XS-800i Hemacytology Analyzer
LIU Wen ZHENG Xin LIU Xiaomin
Department of Clinical Laboratory,Cancer Center of Sun Yat-sen University,Guangzhou 510060,China
[Abstract] Objective To evaluate the ability of PLT counting anti-interference in RBC fragment interference experiment on SYSMEX XE-5000 and XS-800i hemacytology analyzer in laboratory. Methods Counting PLT in RBC fragment interference experiment with XE-5000 electric impedance(PLT-I),XE-5000 optical(PLT-O)and XS-800i electric impedance methods. Compare and analyze the data according to SPSS12.0. Results There were significant correlations(P>0.05)and good repeatability in the results among three methods in normal PLT. In High concentrations group,the result of the methods and control group were statistically significant(P<0.01).But in low concentrations group,PLT-O shows its excellent ability of anti-interference in RBC fragment experiment. Conclusion For counting PLT with RBC fragment interference,XS-800i electric impedance has common ability to anti-interference the same as XE-5000 PLT-I. The result also showed that the XE-5000 PLT-O method is better than XE-5000 PLT-I and XS-800i electric impedance for anti-interference in RBC fragment interference.
[Key words] XE-5000;XS-800i;PLT counting;RBC fragment interference experiment
血小板的主要功能之一是促进止血和加速凝血,同时血小板还有维护毛细血管壁完整性的功能[1]。血小板在止血和凝血过程中,具有形成血栓、堵塞创口、释放与凝血有关的各种因子等功能[2]。而恶性实体肿瘤中血小板增多可能导致凝血异常,如血栓形成和出血倾向,血小板对肿瘤的疾病进展和转移方面起着重要作用,因而血小板检测结果往往对临床医生起到重要的提示作用。而肿瘤患者经药物治疗后,血细胞形态常会出现改变,少量红细胞会出现破碎现象,导致对血小板检测的干扰。目前,血细胞分析仪对血小板检测的方法主要有两种,即电阻抗法(PLT‐I)和荧光法(PLT‐O)[3]。采用传统电阻抗法对血小板计数具有快速、精密度高、重复性好等优点;但易受红细胞碎片、细菌等“非血小板颗粒”的干扰,容易造成血小板数目的假性增高。因而在血常规检测中判定红细胞碎片干扰血小板的有无并作出排除 ......