当前位置: 首页 > 期刊 > 《应用生理学杂志》 > 2001年第6期 > 正文
编号:11132953
Left ventricular wave speed
http://www.100md.com 《应用生理学杂志》
     1 Department of Medicine and Physiology and Biophysics, University of Calgary, Calgary, Alberta, Canada T2N 4N1;

    2 Physiological Flow Studies Group, Department of Bioengineering, Imperial College of Science, Technology and Medicine, London, SW7 2BY United Kingdom

    ABSTRACT

    Left ventricular (LV) wave speed (LVWS) was studied experimentally and confirmed in theory. Combining the definition of elastance (E) with the equations for the conservation of mass and momentum shows that LVWS is proportional to the square root of ELA, where L is long-axis length and A is the cross-sectional area, and the density of the blood. (We defined ELA = , where is compressibility.) We studied nine open chest, anesthetized dogs, three of which were studied during caval constriction when LV end-diastolic pressure was 0 mmHg. The hearts were paced at ~90 beats/min, and LV cross-sectional area was measured by using two pairs of ultrasonic crystals; E was calculated from the LV pressure-area loop. A pulse generator was connected to the LV apex, and LVWS was measured by using two pressure transducers: one near the apex and the other near the base. Their distance was measured roentgenographically and compared with the diameter of a reference ball. LVWS ranged from ~1 m/s during diastole to ~10 m/s during systole. The slope of the log c (where c is wave speed) vs. log was 0.546, which is in agreement with theory (0.5). When0, LVWS was ~1.5 m/s.

    keywords:left ventricle; elastance; distensibility

    INTRODUCTION

    BECAUSE THE LEFT VENTRICLE (LV) profoundly changes its elastance during the cycle of contraction and relaxation (13), wave speed must also change significantly. At present, there is only one report in the literature that relates wave speed to elastance, and those measurements were made during only a part of the cardiac cycle (10). As we intend to study LV diastolic filling and systolic ejection using wave-intensity analysis, we designed a protocol to measure wave speed during all phases of the cycle. Our findings are supported by a theoretical discussion.

    METHODS

    Instrumentation. The experiments were performed in nine healthy mongrel dogs weighing between 21 and 30 kg. Dogs were anesthetized by thiopental sodium (20 mg/kg) followed by fentanyl citrate (30 μg · kg1 · h1) and ventilated with a 1:1 nitrous oxide-oxygen mixture with 1.6-2% of isoflurane. The rate of a constant-volume respirator (model 607, Harvard Apparatus, Natick, MA) (tidal volume, 15 ml/kg) was adjusted to maintain normal blood-gas tensions and pH. Body temperature was maintained at 37°C using a circulating-water warming blanket and a heating lamp. An albumin-saline solution was infused through the jugular vein to maintain the blood pressure.

    A volume pulse generator was connected to the LV via a purse-string suture at the apex (Fig. 1). It consisted of a specially fabricated hollow cylinder with an inner diameter of 4.0 cm and volume of 153 ml, which contained a balloon that was connected to a counterpulsation pump (Datascope, Paramus, NJ). The cylinder was filled with blood, and all bubbles were carefully removed. Two catheter-tip manometers (SPC-482A, Millar Instruments, Houston, TX) were introduced retrogradely into the LV via the common carotid arteries, one near the apex and the other near the base (Fig. 1), and were referenced using their fluid-filled lumens so that absolute values of pressure could be ascertained. The tips of the two manometers were positioned on a straight line with the end of the nozzle, and the distance between them was measured on the radiograph. Two pairs of ultrasonic crystals (Sonometrics, London, Ontario) were implanted in the LV endocardium to measure the anterior-posterior and septum-free wall dimensions. The pericardium was then loosely sutured to approximate the normal constraint (9). The heart rate was controlled at ~90 beats/min by right atrial pacing. A two-channel laboratory stimulator (model S88, Grass Medical Instruments, Quincy, MA) was used to trigger the counterpulsation pump, which could be adjusted to inflate and deflate the balloon (duration, ~100 ms) at any chosen instant during the cardiac cycle. A smaller inflating volume was chosen during systole (5 ml) than during diastole (13 ml) to produce pressure increments of similar sizes. A pneumatic cuff (In Vivo Metric, Healdsburg, CA) was placed around the inferior vena cava (IVC).

    At the end of experiment, the distance between the two manometer tips (assumed to be in the same horizontal plane) was measured from a single-plane, cut-film radiograph taken with the use of a fluoroscope and a metal ball of known diameter (1.90 cm) placed beside the LV as a reference. Knowing the time interval required for the wave to travel from one manometer to the other and the distance between them, we could calculate wave speed.

    Experimental protocol. A series of IVC occlusions was performed to define LV elastance (see below). The dog was then allowed to recover for 3-5 min before we started the wave-speed measurements. The balloon could be inflated at any instant during the cardiac cycle, which we divided into 15 phases with respect to the marker on the pump. The experiment started by inflating the balloon at the beginning of systole. We then moved the inflation point to the next phase, fired the balloon, and then proceeded to the next phase until the whole cycle had been studied. Between each inflation, we allowed an interval of 3-5 min for recovery.

    In three dogs, we reduced LV transmural diastolic pressures to negative values before measuring wave speed. Whereas profound arterial hypotension was avoided, the IVC was constricted until LV diastolic pressure became negative (1 to 5 mmHg). This protocol was the same as that described above, except that measurements were made only during diastole.

    In all experiments, we sought to achieve a quasi-steady state so that, later, we could subtract the pressure waveform of the previous control beat from that of the balloon inflation beat, thereby isolating the signal due to the generated pulse (see below).

    Data analysis. After preamplification (model VR-16, Electronics to Medicine, Honeywell, White Plains, NJ), the analog hemodynamic signals were passed through an antialiasing, low-pass filter with a cutoff frequency of 500 Hz and were recorded using an Intel Pentium computer with acquisition software (Sonolab, Sonometrics, Ontario). Data were sampled at 1,600 Hz. To determine the incremental increase in pressure due to the pulse, the balloon inflation beat was subtracted from the immediately preceding control beat (Fig. 2). The transmission interval could be measured by either of two methods: 1) by shifting the base signal to best match the apex signal and by multiplying the number of sampling points shifted by the sampling interval, 0.625 ms, or 2) by fitting the leading edge of the pressure pulses to straight lines and measuring the times of intersection with the abscissa. The first method was generally adopted during diastole, and the second method was used to increase the resolution during systolic ejection.

    Having assumed that the long-axis length remained constant, we determined the zero-pressure intercept by the standard Suga-Sagawa method (13). The end-systolic pressure-area points recorded during IVC occlusion were fitted to a straight line that was extrapolated to the abscissa.

    THEORY

    Wave propagation in the LV is modeled by one-dimensional flow in an elastic tube. The expression for mass conservation for incompressible blood is

    (1)

    where A is the cross-sectional area, U is the average velocity across the vessel, and subscript x indicates partial differentiation with respect to distance along the vessel. Neglecting viscous dissipation, the momentum equation is

    (2)

    where P is the pressure, is the density of the blood, and subscript t is the partial differentiation with respect to time. Solution of these equations relies on finding a functional relationship between the vessel A and the local P (i.e., a "tube law" relationship)

    (3)

    The ventricle is considered to be an elastic conduit whose properties vary in time t. It is assumed that the properties of the wall and the flow within the ventricle can be described with a single spatial variable x, measured along the axis of the ventricle. The instantaneous ventricular pressure, Plv(t), is related to the instantaneous volume of the ventricle, V(t), by the elastance, E(t) (8)

    (4)

    where Plv(t) is the spatial average of the pressure P(x,t), Vlv(t) (where Vlv is left-ventricular volume) is the integral of A(x,t) over the length of the ventricle L, and Vd = AdL

    Substituting these expressions into the definition of E, we obtain the integral relationship

    (5)

    where Ad is the zero-pressure intercept and L is assumed to be a constant. However, variation of the long axis can easily be accommodated into the theory by setting A(x,t) = 0 over the part of the ventricle that is obliterated during contraction. If there is homogeneity in x (i.e., the local elastic behavior of the ventricle is the same throughout the ventricle), then the integrand must be zero

    (6)

    This equation for the local P and A in terms of the time-varying E of the ventricle provides the tube law necessary to solve Eqs. 1 and 2. In the APPENDIX, these equations are written in their canonical matrix form from which the wave speed, c, can be determined by solving for the eigenvalues of the matrix in Eq. A3

    (7)

    We note that, if we define the "compressibility" of the LV, = ELA, or equivalently in terms of the measurable P and A, = PA/(A Ad), then the c is simply

    RESULTS

    A typical result of apex-to-base transmission of the pressure pulse is shown in Fig. 3. Wave speeds varied over an order of magnitude from ~1 m/s during diastole to 10 m/s during systole. Figure 4 shows measured values of wave speed in temporal relation to a pressure-area loop of a representative cardiac cycle.

    Figure 5 shows the log-log plots of wave speeds vs. compressibility for the six experiments in which the whole cardiac cycle was studied. The slope of the linear regression line for each dog represents the power relationship between wave speed and compressibility from the experiments ranging from 0.43 to 0.70. Pooled data are shown in Fig. 6; the regression line for the combined data yields c = 0.9740.546, which matches well with the theory c = = 0.9760.5, where is 1,050 kg/m3 (5).

    The pooled data from the negative-elastance experiments are plotted in Fig. 7 on an expanded linear scale. The regression line for the positive data is the one determined in Fig. 6. The average wave speed during periods when compressibility was negative was 1.34 m/s.

    DISCUSSION

    One advantage of wave-intensity analysis is that it can separate the upstream and downstream events using the pressure (dP) and velocity changes (dU) measured at a single point in the artery (6, 7, 14). With the assumption that they are additive, the dP caused by the forward and backward traveling waves can be calculated by dP± = 1/2(dP ± cdU) and the velocity changes by dU± = ±1/2(dP/c ± dU), where + and signify the forward and backward waves, respectively. The power (W/m2) carried by the forward and backward waves is measured by their wave intensities, which can be calculated by 1/4c(dP + cdU)2 and 1/4c(dP cdU)2, respectively. Note, however, that these calculations require knowledge of the wave speed.

    A wave is the result of interaction between inertial and restoring forces. When wave propagation in the LV is considered, the restoring force is due to chamber elastance, which varies continuously through the cardiac cycle. The theory shows that the square of wave speed is linearly proportional to ELA (i.e., compressibility), not elastance itself, as suggested by Shishido et al. (10). Their conclusion resulted from measurements done exclusively during isovolumic conditions when the cross-sectional area changes little. During periods in the cardiac cycle when cross-sectional area is constant, the two expressions are equivalent.

    In principle, measurements of wave speed are affected by the convection of blood during systolic ejection and diastolic filling. In our experiments in which the generated pulse was propagating from the apex to the base, the measured value in systole is the wave speed plus the flow speed, and, in diastole, it is the wave speed minus the flow speed. The peak systolic flow in the outflow tract is ~1 m/s, which is less than one-tenth the measured systolic wave speed. In diastole, the convection due to the elastance and cross-sectional area filling waves may be more important because their peak magnitudes (~0.4 m/s) may be approximately one-half that of the measured wave speed. The convection correction in diastole, which increases the value of wave speed, compounded with the smaller correction in systole, which decreases the value of wave speed, tend to reduce the measured slope in the log-log plots in Figs. 5 and 6 by raising the low values and lowering the high values of wave speed. Thus correction for convection could bring the measured exponent 0.546 even closer to the theoretical value of 0.5.

    During diastolic filling, LV pressure sometimes falls below zero. The simple theory above predicts that negative LV pressure yields a negative elastance and an imaginary wave speed, which is not reasonable. When the transmural pressure changes from positive to negative, compression stress and bending moments may be induced with effects on wave speed that cannot be predicted from the simple theory; therefore, when elastance is negative, wave speed has to be determined experimentally. We have found that wave speeds are consistently similar at near-zero positive and negative values of elastance.

    There are limitations to this model. The shape of the LV lumen is approximately that of a hemiellipsoid, surrounded by several muscle layers arranged in different directions. The LV wall is mostly muscular, but some of the septum is membranous. Only the upper one-third of the septum is smooth and membranous, but the remainder of the inner LV wall is ridged by muscles, the trabeculae carneae. The wall is also thinner at the apex than the base (12). This complicated structure, however, has been simulated by using one-dimensional models with respect to the systolic ejection (15) and isovolumic contraction (10) periods. Using an in vitro model, Steen and Steen (11) determined that blood moves simultaneously as a flow column during early mitral filling.

    The wave in the LV was assumed to travel as a plane, where the velocity is averaged across the cross-sectional area. By applying the tube law, no assumption of a uniform cross-sectional area is required, although we assumed that the long axis remained constant. We have assumed homogeneous time-varying compressibility, but this might not be true near the apex. The assumption might be improved by incorporating more complicated location-dependent properties, which might include time-varying activation from the central left of the septum, the high anterior and apical posterior paraseptal areas (1, 2, 4).

    The assumption of homogeneous time-varying compressibility implies that each part of the LV is mechanically activated simultaneously. During systole, ~2 ms were required for the wave to travel from one pressure transducer to the other, and, during diastole, 16 ms were required. These times are to be compared with the ~12 ms required for complete electrical activation (2, 3) and 22 ms for mechanical activation (4). As compressibility can be assumed to be relatively constant during diastole and as the transit time during systole was relatively small, potential effects of compressibility changing during the interval of wave transit can be ignored.

    We conclude that the wave speed in the LV depends only on the instantaneous compressibility, which can be expressed in terms of the instantaneous elastance and volume of the ventricle. Our experiments showed that this relationship holds very well over the whole of the cardiac cycle during which the elastance of the ventricle varies by nearly two orders of magnitude. In the canine LV, we found c = 0.9740.546 m/s, where = ELA, except when is negative, when the wave speed is approximately constant with c = 1.34 m/s.

    APPENDIX

    The relationship of cross-sectional area, local pressure, and the elastance can be stated as (Eq. 6)

    Differentiating, we obtain the differential relationships between the local area and the pressure and area

    where Et = dE/dt is an ordinary differential, because of the assumption of uniform elastance. Substituting these relationships, the mass conservation equation can be written in terms of P and U

    (A1)

    The mass (Eq. A1) and momentum (Eq. 2) equations can be written in the canonical matrix form

    This system of equations is hyperbolic and can be solved using the method of characteristics. The eigenvalues of the matrix found from the characteristic equation

    are = U ± c, where c is defined as

    ACKNOWLEDGEMENTS

    We acknowledge the excellent technical support provided by Cheryl Meek, Rozsa Sas, and Gerald Groves.

    FOOTNOTES

    J. V. Tyberg is a Medical Scientist of the Alberta Heritage Foundation for Medical Research (Edmonton). The study was supported by a grant-in-aid from the Heart and Stroke Foundation of Alberta (Calgary) to J. V. Tyberg.

    Address for reprint requests and other correspondence: J. V. Tyberg, Professor of Medicine and Physiology and Biophysics, Univ. of Calgary Health Science Centre, 3330 Hospital Drive NW, Calgary, Alberta, Canada T2N 4N1 (E-mail: jtyberg@ucalgary.ca).

    The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.

    Received 25 June 2001; accepted in final form 14 August 2001.

    REFERENCES

    1.Durrer, D, Roos JP, and Buller J. The spread of excitation in canine and human hearts. In: Electrophysiology of the Heart, edited by Traccardi B, and Marchetti G.. New York: Pergamon, 1965.

    2.Durrer, D, VanDam RT, Freud GE, Janse MJ, Meijler FL, and Arzbaecher RC. Total excitation of the isolated human heart. Circulation 41: 899-912, 1970.

    3.Fisch, C. Electrocardiography. In: Heart Disease: a Textbook of Cardiovascular Medicine (5th ed.), edited by Braunwld E.. Philadelphia, PA: Saunders, 1997, chapt. 4, p. 108-152.

    4.Hotta, S. The sequence of mechanical activation of the ventricle. Jpn Circ J 31: 1568-1572, 1967.

    5.McDonald, DA. Blood Flow in Arteries. London: Arnold, 1974, p. 259.

    6.Parker, KH, and Jones CJH Forward and backward running waves in the arteries: analysis using the method of characteristics. J Biomech Eng 112: 322-326, 1990.

    7.Parker, KH, Jones CJH, Dawson JR, and Gibson DG. What stops the flow of blood from the heart? Heart Vessels 4: 241-245, 1988.

    8.Sagawa, K. The ventricular pressure-volume diagram revisited. Circ Res 43: 677-687, 1978.

    9.Scott-Douglas, NW, Traboulsi M, Smith ER, and Tyberg JV. Experimental instrumentation and left ventricular pressure-strain relationship. Am J Physiol Heart Circ Physiol 261: H1693-H1697, 1991.

    10.Shishido, T, Sugimachi M, Kawaguchi O, Miyano H, Kawada T, Matsuura W, Ikeda Y, and Sunagawa K. Novel method to estimate ventricular contractility using intraventricular pulse wave velocity. Am J Physiol Heart Circ Physiol 277: H2409-H2415, 1999.

    11.Steen, T, and Steen S. Filling of a model left ventricle studied by colour M mode Doppler. Cardiovasc Res 28: 1821-1827, 1994.

    12.Streeter, DD. Gross morphology and fiber geometry of the heart. In: Handbook of Physiology. The Cardiovascular System. The Heart. Bethesda, MD: Am. Physiol. Soc, 1979, sect. 2, vol. I, chapt. 4, p. 61-112.

    13.Suga, H, and Sagawa K. Instantaneous pressure-volume relationships and their ratio in the excised, supported canine left ventricle. Circ Res 35: 117-126, 1974.

    14.Sun, YH, Anderson TJ, Parker KH, and Tyberg JV. Wave-intensity analysis: a new approach to coronary dynamics. J Appl Physiol 89: 1636-1644, 2000.

    15.Verdonck, P, Vierendeels J, Riemslagh K, and Dick E. Left-ventricular pressure gradients: a computer-model simulation. Med Biol Eng Comput 37: 511-516, 1999.(Jiun-Jr Wang, Kim H. Park)